ARCHITECT AND ENGINEER

Specifications

The following description is provided to assist architects and engineers in specifying the installation of the Roof Drain De-Icing Systems cable Jig. 

Supply and install (quantity____________) 4RDDJ22 Canale or Scupper Type-A Installation

Supply and install (quantity____________) 6RDDJ22 Primary Drain Type-B Installation

Supply and install (quantity____________) CABLE KEEPER Type-C Installation

Supply and install (quantity____________) CABLE KEEPER Type-D Installation

Type-A and Type-B Installations shall consist of a polar array of multiple metal parallel pair tracks, RAYS. Common roof and  gutter heat cable as specified under section_____________ is systematically placed in a specific pattern through all of the cable tracks on the roof drain(s) as specified under section_____________.

Type-C Installations shall consist of a rectangular array of multiple metal parallel pair tracks, CABLE KEEPERS.  Common roof and gutter heat cable as specified under section_____________ is systematically placed in a specific pattern through all of the cable tracks as specified under section_____________.  In heavy snow territories an upper lattice, expanded metal, is to be provided and systematically riveted to the face of the CABLE KEEPERS to act as a framework and  heat sink to greatly improve snow melting capabilities.

Type-D Installations shall consist of tandomly series of multiple metal parallel pair tracks, CABLE KEEPERS.  Common roof and gutter heat cable as specified under section_____________ is systematically placed in a specific pattern through all of the cable tracks as specified under section_____________.

The Jig is designed so as not to anchor directly to the roofing system.  Appropriate accessories are offered with the Jig.  The completed apparatus, including the heat cable, is then mounted on a roof     drainage installation to ensure no ice will form, thereby effectively promoting water flow into the drain during freezing conditions.

 

Contact RDDS, INC. @ 303-549-4508

or

wlgraves@gmail.com

 

 

Text Box:  ROOF DRAIN DE-ICING SYSTEMS INC.

No Dammed Ice

6RDDJ22 Cable Jig             for Primary  Drainage of Flat Roof

4RDDJ22 Cable Jig             For Canale or Scupper Style Roof Drainage

RDDJ– GRID   Snow Load Reduction utilizes multiple  CABLE KEEPERS  in a field ofofattached to expanded metal

A.

B.

C.

Roof Surface

CABLE KEEPERS

FRAME

D.

1-each 6RDDJ22 Jig requires One FRAME

Six  KEEPERS

Installation Types:

Self-Regulating Cable is not provided  within the RDDJ system but is ordered separately.  See details within the Catalog